Fyfe Co. LLC logo graphicFyfe Co. LLC tagline graphic
Fyfe Co. LLC tagline graphic

Product Details

 Tyfo® CIS Inhibitor Layer 2

  DESCRIPTION
  Tyfo® CIS Layer 2 is a single-component, clear, waterbased liquid with a mild odor. It may be
  applied by roller or spray following the application of Tyfo® CIS Layer 1. Layer 2 controls the pH,
  purges and encapsulates water-soluble chlorides, fills voids in the concrete, and inhibits further
  penetration of moisture. Layer 2 also acts as a contact corrosion inhibitor on the reinforcing steel.
  After receiving both Layers 1 & 2, the exposed surfaces are cleaned by washing with fresh water or
  by abrasive blasting. All exposed steel is then treated with the Tyfo® CB material and the concrete
  section is restored using Tyfo® P or Tyfo® PF as required.

  USE
  Tyfo® CIS Layer 2 is used with the Tyfo® Concrete Repair System on new or old concrete surfaces
  to seal porosity, increase compression strength, maintain pH, protect from acid and alkali attack,
  pacify and extract chlorides, and inhibit embedded steel corrosion.

  ADVANTAGES
  • Ease of application
  • Can be applied to horizontal, vertical or overhead surfaces
  • Restores properties of deteriorating Portland concrete cement
  • Can penetrate concrete 2 to 3 inches, depending upon existing porosity
  • Dramatically improves condition of substrate prior to repairs
  • Protects new concrete
  • For new and old structures
  • Non-toxic

MATERIAL PROPERTIES
Property ASTM Method Typical Test Value*
Corrosion Inhibition
C-876
50% reduced voltage in 14 days
(400 to 200mV)
Compression Strength
C-42
Increases 2,000 psi
(13.8 MPa)
Hardness Increase
 
New concrete
C-418
14%
Deteriorated concrete

C-414

64%
Porosity Reduction   90%
Solubility   Complete in water
pH   12.0

Soluble Chloride Reduction

70%
Acid Reactivity Reduction
90%
Density
9.1 lbs./gal. (4kg/3.79L)
VOC
Less than 1%
* Specification values can be provided upon request.